Lightning Protection

  • ADDITIVES FOR ENHANCED CONDUCTIVITY
    ADDITIVES FOR ENHANCED CONDUCTIVITY
    Earth improving additives for enhancement of the conductivity of the earthing connection system. These additives enrich the content of mineral soluble salts improving the conductivity as well as extending their duration...

  • CDI-CDR - Discharge counter
    CDI-CDR - Discharge counter
    Whether in a suggesting or obliging manner, the standards and norms may address the issue of the installation of lightning discharge counters in order to keep track of the ageing of the Lightning Protection System and to...

  • CPT Nimbus
    CPT Nimbus
    Active protection. CPT NIMBUS lightning rods with ESE (Early Streamer Emission) technology are designed and manufactured according to state-of-the art technology in AISI 316 stainless steel. The impact of the lightning...

  • DOWN CONDUCTOR
    DOWN CONDUCTOR
    System in charge of conducting the lightning discharge current down to the earth connection system in a safe and controlled manner CPT Code Reference Description Technical Info 77920200 TUB-PROT BAJ 3...

  • EARTH CONNECTION
    EARTH CONNECTION
    CPT Code Reference Description Technical Info 77931100 REGL EQUIPOT ARQ Equipotential terminal strip.   77932000 JAB INOX Stainless steel earth rod 2 m, diameter 14 mm...

  • FRANKLIN - Franklin Lightning rods
    FRANKLIN - Franklin Lightning rods
    Passive protection with a Franklin rod that naturally ionises the environment for a cone-shaped protection volume. CPT Code Reference Description Technical Info 77900400 P-FRANKLIN Franklin top of...

  • HEAD ADAPTER
    HEAD ADAPTER
    Adapting piece for fixation of the NIMBUS lightning rod to the down-conductor, thereby guaranteeing electrical continuity between both components. CPT Code Reference Description Technical...

  • INSPECTION PIT
    INSPECTION PIT
    An inspection pit makes it possible to conduct regular inspections of the electrodes of the earthing connection system in a lightning protection system. CPT Code Reference Description Technical...

  • LIGHTNING ROD MAST
    LIGHTNING ROD MAST
    The mast provides the required height for the lightning rod to protect an exposed area under the desired radius of coverage. CPT Code Reference Description Technical Info 77903010 MAST 3M FEG Mast of 3 m...

  • MAST FASTENING ACCESSORIES
    MAST FASTENING ACCESSORIES
    Accesories for fixation of the mast to either a wall or a roof structure by means of screws or in an embedded way. CPT Code Reference Description Technical Info 77904100 PIE SOP MAST TEJ Mast base support...

  • MISC. LIGHTNING RODS
    MISC. LIGHTNING RODS
      CPT Code Reference Description Technical Info 77908100 CABLE-TRZ Cu 50 50 mm2 round copper cable.   77908200 CABLE-TRZ Cu 70 70 mm2 round copper cable.   77909100 SOP-CABLE...

  • SPARK GAP
    SPARK GAP
    Systems for equipotentially bonding metal masses (external spark gaps) as well as for bonding the earth connections of a Lightning Protection System. CPT Code Reference Description Technical...

  • TESTERS - LR status tester
    TESTERS - LR status tester
    Testing the different components for their correct functioning is a key maintenance practice in Lightning Protection Systems. The tester performs verification processes on the Early Streamer Emission circuit and does check...